DEPARTMENT OF SPORTS
Punjab | Mohali |
- Download
Time left to bid
13
Days5
Hours4
MinutesTender Roadmap
Publish Date
07 Jul 2025
Tender is published for seller Participation.
Bid Submission End Date
11 Aug 2025
Last day to participate Tender on Gem platform.
Evaluation Date
11 Aug 2025
Technical committe will evaluate Bid and Open Results.
Earnest Amount | ||||||||||
7.5 L | ||||||||||
Tender Amount | ||||||||||
1.5 Cr | ||||||||||
Department | ||||||||||
Item Category | ||||||||||
Medical Equipments - Physiotherapy Equipment | ||||||||||
Purchaser Address | ||||||||||
Punjab Yuva Bhawan Sector 42 A Chandigarh | ||||||||||
Work Description | ||||||||||
Corrigendum : Purchase Of Sports Exercise Physiology Lap Equipments - Cardiopulmonary Exercise Testing System System Should Be Compact Can Be Used In Laboratory Operation And Low Maintenance Costs And Easy Servicing. System Should Be State Of The Art Computerized Telemetry Breath Test Analyzer For On-line Breath By Breath Measurement Of Exercise Test Of Respiratory System To Measure Following Parameter: Time, Ve, Bf(rr), Hr, Feo2, Feco2, Peo2, Peco2, Vo2, Vco2, Ve/vco2(eqco2), Ve/vo2(eqo2), Rq(rer), Vd/vt, Vo2/kg, Vo2/kg/hr, Met, Watt(work), Hr, Ttot, Ti, Te, Ti/te, Ti/ttot, Pef, Pif, Br, Vet, Sum, Tv/te, O2 Kinetics, Oxygen Deficit, Oxygen Debt Parameters And Indirect Calorimetric. Wireless Hr Recording System, Indirect Cardiac Output By Wassermann Algorithm System Should Comply Ats And Ers Guide Line And It Should Be Ce Certified., Iso Certified System Should Have Automatic Ambient Conditions Measuring System. System Should Work Under Temperature Range 0 To 50 Celsius. System Should Have Facility For Automatic Calibration Of Analyzers. Volume Transducer Calibration With Precision Calibration Syringe. System Should Meet Following Technical Specification Flow Rate Measurement: Measuring Headpiece Should Be Either Through Turbine /dvt/ Pneumotach And Dead Space Less Then 40 Ml, It Should Not Be Affected By Humidity , Flow Range +/- 18 L/s And Accuracy 2% Oxygen Analyser : Should Be Either Electrochemicalcell/paramagnetic And Measurement Range 0- 100 %,response Time T90 100 Ms And Accuracy +/-0,04 % And- Resolution 0,02 %carbon Dioxide Analyser : Should Be Ndir (infraredabsorption) And Measurement Range 0 - 10 %,-response Time T90 90 Ms , Accuracy +/- 0,04 %, Andresolution 0,02 % Software Should Support Latest Windows Or Latest Andin Corporate Customized Predicted Normal Equations.software Should Be Capable Of Changing Graphics Displays During Real Time Testing. System Should Have Facility For Automatic Treadmill Or Bicycle Ergo Meter Control.
|
||||||||||
My Evaluation Notes | ||||||||||
|