DEPARTMENT OF SPORTS
Punjab | Mohali |
- Download
Time left to bid
13
Days5
Hours4
MinutesTender Roadmap
Publish Date
07 Jul 2025
Tender is published for seller Participation.
Bid Submission End Date
11 Aug 2025
Last day to participate Tender on Gem platform.
Evaluation Date
11 Aug 2025
Technical committe will evaluate Bid and Open Results.
Earnest Amount | ||||||||||
9 L | ||||||||||
Tender Amount | ||||||||||
1.8 Cr | ||||||||||
Department | ||||||||||
Item Category | ||||||||||
Medical Equipments - Physiotherapy Equipment | ||||||||||
Purchaser Address | ||||||||||
Punjab Yuva Bhawan Sector 42 A, Chandigarh | ||||||||||
Work Description | ||||||||||
Corrigendum : Purchase Of Sports Physiotherpy Lab Equipments - Focused Shockwave Therapy The Device Should Be Suitable For Musculoskeletal Use. Should Be A Focused Shockwave Based On Piezo Mechanism. Should Have Multi Array Type Piezo Electric Hand Piece. Should Have Accuracy Of The Shock Wave Generation Cycle(frequency)0~8 10% Should Have Software-based Operating System The Unit Should Have Large Color Touch Screen For Ease Of Operation. The Unit Should Have Accuracy Of The Operating Frequency 0~7000shock 10% The Unit Should Have Maximum Energy Density 0.702 M J/ (when Setting At 23 Levels) 15% Should Have Shock Wave Penetration Depth 40 20%. Should Have Maximum Focus Size. 78 1.78 15.81 20% Should Have Maximum Pressure 44.01 0.65 Mpa The Unit Should Be Supplied With Piezo Hand Piece And Elastomer Gel Padas Of 8 Different Sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, And 44mm. The Life Span Of Hand Piece Should Be Of Up To 10 Million Shocks. Should Be Supplied With Trolley With Castor Wheels. Dimension Of The Device Should Be Approximated 500mmx700mmx 1000mm Should Have Ce Or Usfda Certified., High Laser Therapy Should Be Class Iv High Level Laser Therapy System Should Have A Real-time Operating System Technology Should Have Maximum Laser Should Be Class Iv High Level Laser Therapy System Should Have A Real-time Operating System Technology Should Have Maximum Laser Power Output Of 15 Watts Should Have Wavelengths Of 810 Nm & 980 Nm Should Have An Aiming Beam Of 650nm, Should Have 2 Operating Modes: Continuous Wave Or Pulsed Applicate And Piece Should Have Embedded Finger Switch And Light, Should Have A Technology To Customize Patient Treatment Based On Conditions, Body Area, Body Type, Skin Type, Chronicity And Absorption Characteristics Applicator Should Have A Fused Silica Composition Massage Ball At The Point Of Contact Of Applicator And Skin.
|
||||||||||
My Evaluation Notes | ||||||||||
|